BPLCV - F10, ACRYLD ACRYLIC ENAMEL NON-LEAD COLORS
- MSDS: BPLCV
- Manufacturer: N P
- Product Name: F10, ACRYLD ACRYLIC ENAMEL NON-LEAD COLORS
- National Stock Number: 8010-00N021663
Product Identification
Contractor
Telephone: 800-251-2486/216-566-2242
Cage: 54636
Ingredients
CALCIUM CARBONATE, WHICH MAY BE PRESENT @ HAZ LEVELS
RTECS: 9999999ZZ
PROTECTION AGAINST NON-VOLATILE MATERIALS IN
RTECS: 9999999ZZ
STANDARDS 1910.94, 1910.107, 1910.108.
RTECS: 9999999ZZ
W/SKIN/EYES. COATING MAY CNTN MATL CLASSIFIED AS
RTECS: 9999999ZZ
1.0
CAS: 112-07-2
RTECS: KJ8925000
Fraction By Weight: <5%
ACGIH TLV: 50 PPM (MFR)
1.0
CAS: 13463-67-7
RTECS: XR2275000
Fraction By Weight: 0-20%
OSHA PEL 15 MG/M3 TDUST
ACGIH TLV: 10 MG/M3 TDUST; 9293
ACRYLIC POLYMER; (PROPRIETARY INGREDIENT)
Fraction By Weight: 25-35%
TO TITANIUM DIOXIDE @ 250 MG/M3 DEVELOPED
RTECS: 9999999ZZ
MAINTAINABLE IN WORKPLACE. RPTS HAVE ASSOC RPTD &
RTECS: 9999999ZZ
(TOLUENE CAS # 108-88-3) APPEARS ON NAVY LIST OF
RTECS: 9999999ZZ
PROFESSIONALS CONCERNING LATEST HAZ LIST INFO &
RTECS: 9999999ZZ
CLEARLY DEMONSTRATED DOSE-RELATED ADVERSE EFTS ON
RTECS: 9999999ZZ
W/ADMIN OF ETHYLENE GLYCOL MONOBUTYL ETHER (EGBE) &
RTECS: 9999999ZZ
(EXTRACTED FROM DHHS (NIOSH) PUBLICATION NO. 90-118)
RTECS: 9999999ZZ
INDICATIONS OF EXCESS EXPOS TO VAP/SPRAY MISTS. RED
RTECS: 9999999ZZ
DISPOSE OF IN ACCORDANCE WITH FEDERAL,
RTECS: 9999999ZZ
LBLG. DO NOT TAKE INTERNALLY. KEEP OUT OF REACH
RTECS: 9999999ZZ
INHALING CONTENTS CAN BE HARMFUL/FATAL. USE ONLY
RTECS: 9999999ZZ
10
CAS: 123-86-4
RTECS: AF7350000
Fraction By Weight: 1-15%
OSHA PEL 150 PPM;200 PPM STEL
ACGIH TLV: 150 PPM;200 PPM STEL
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
KEROSENE (PETROLEUM), HYDROTREATED; (MINERAL SPIRITS). VP
CAS: 64742-47-8
RTECS: OA5504000
Fraction By Weight: <5%
OSHA PEL 500 PPM (MFR)
ACGIH TLV: 100 PPM (MFR)
22
CAS: 108-88-3
RTECS: XS5250000
Fraction By Weight: 1-10%
OSHA PEL 200 PPM/150 STEL
ACGIH TLV: 50 PPM; 9293
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
7.1
CAS: 100-41-4
RTECS: DA0700000
Fraction By Weight: <5%
OSHA PEL 100 PPM;125 PPM STEL
ACGIH TLV: 100 PPM;125 PPM STEL
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
5.9
CAS: 1330-20-7
RTECS: ZE2100000
Fraction By Weight: 25-45%
OSHA PEL 100 PPM;150 PPM STEL
ACGIH TLV: 100 PPM;150 PPM STEL
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
SOLVENT NAPHTHA (PETROLEUM), LIGHT AROMATIC; (LIGHT
CAS: 64742-95-6
Fraction By Weight: 1-5%
ACGIH TLV: 100 PPM (MFR)
70
CAS: 78-93-3
RTECS: EL6475000
Fraction By Weight: 0-5%
OSHA PEL 200 PPM;300 PPM STEL
ACGIH TLV: 200 PPM;300 PPM STEL
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EXPOS MAY BE BY INHAL/SKIN/EYE CONT,
DPNDG ON CNDTNS OF USE TO MINIMIZE EXPOS, FOLLOW RECOM FOR PROPER
USE, VENT, & PERSONAL PROT EQUIP. ACUTE: IRRIT OF EYES/SKIN/RESP
SYS. MAY CAUSE NERV SYS DEPRESS. EXTREME OVEREXP MAY RSLT IN UNCON
& POSS DEATH. CHRONIC: METHYL ETHYL KETONE MAY INCR NERV SYS EFTS
(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ: OF OTHER SOLV. LIM EVIDENCE EXISTS
LINKING CERTAIN NICKEL CMPDS TO CANCER IN ANIMALS & POSS HUMANS,
HOWEVER NO DIRECT EVIDENCE EXISTS THAT NICKEL ANTIMONY TITANATE IS
CARCIN. PRLNG OVEREXP T O SOLV INGRED MAY CAUSE ADVERSE EFTS
TOLIVER, URIN, BLOOD FORM, CARDIO-VASCULAR, & REPROD SYS. RATS
EXPOS (ING 11)
Medical Cond Aggravated by Exposure:NONE GENERALLY RECOGNIZED.
First Aid
First Aid:INHAL: REMOVE FROM EXPOS. RESTORE BRTHG. KEEP WARM & QUIET.
SKIN: WASH AFFECTED AREA THORO WITH SOAP AND WATER. REMOVE
CONTAMINATED CLOTHING AND LAUNDER BEFORE RE-USE. EYES: FLUSH WITH
LARGE AMOUNTS O F WATER FOR AT LEAST 15 MIN. GET MED ATTN. INGEST:
CALL MD IMMED .
Fire Fighting
Flash Point:50.0F/10.0C
Accidental Release
Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION. VENTILATE AND
REMOVE WITH INERT ABSORBENT.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:CONTENTS ARE FLAM. KEEP AWAY FROM
HEAT/SPARKS/OPEN FLAME. DURING USE & UNTIL ALL VAP ARE GONE: KEEP
AREA VENTD-DO NOT SMOKE. CONSULT NFPA CODE.
Other Precautions:EXTING ALL FLAMES/PILOT LIGHTS, & HEATERS-TURN OFF
STOVES, ELECTRIC TOOLS & APPLIANCES, & ANY OTHER SOURCES OF IGNIT.
USE APPRVD BOND & GROUND PROC. KEEP CONTR CLSD WHEN NOT IN USE.
TRANSFER ONLY TO A PPRVD CONTR W/COMPLETE & APPROP (ING 20)
Exposure Controls
Respiratory Protection:IF PERSONAL EXPOS CANNOT BE CONTROLLED BELOW
APPLIC LIM BY VENT, WEAR A NIOSH/MSHA APPRVD ORG VAP/PARTICULATE
RESP FOR PROT AGAINST MATL. WHEN SAND/WIREBRUSH/ABRAD/BURN/WELD
DRIED FILM, WEAR NIOSH/MSH A APPRVD PARTICULATE RESP FOR (ING 24)
Ventilation:LOC EXHAUST PREF. GEN EXHAUST ACCEPTABLE IF EXPOS TO MATL
IS MAINTAINED BELOW APPLIC EXPOS LIM. REFER TO OSHA (ING 25)
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:WASH HANDS AFTER USING.
Supplemental Safety and Health
FIRE FIGHT PROC: TO PVNT PRESS BUILD-UP & POSS AUTOIGNIT/EXPLO WHEN
EXPOS TO EXTREME HEAT. EXPLO HAZ: REQUIRES SPECIAL PREC. DURING
EMER CNDTNS OVEREXP TO DECOMP PROD MAY CAUSE HLTH HAZ. SYMP MAY NOT
BE IMMED APPARENT. OBTAIN MED ATTN. MATL TO AVOID: DANGEROUSLY
INCR PRESS IN CLOSED CONTAINERS.
Stability
Hazardous Decomposition Products:BY FIRE: CO*2, CO, OXIDES OF METALS IN
INGREDIENTS.
Disposal
Product ID:F10, ACRYLD ACRYLIC ENAMEL NON-LEAD COLORS
MSDS Date:01/01/1987
FSC:8010
NIIN:00N021663
MSDS Number: BPLCV
Waste Disposal Methods:WASTE FROM PROD MAY BE HAZ AS DEFINED UNDER
RESOURCE CONSERVATION & RECOVERY ACT 40 CFR 261. WASTE MUST BE
TESTED FOR IGNITABILITY & EXTRACTABILITY TO DETERM APPLIC EPA HAZ
WASTE NUMBERS. INCIN IN APP RVD FACILITY. DO NOT INCIN CLSD CONTR.
(ING 19)
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.